Loading...
Res 1745 - Review Dev. Ord. COUNCIL BILL NO. 2489 RESOLUTION NO. 1745 A RESOLUTION TO INITIATE THE ANNUAL REVIEW OF THE WOODBURN DEVELOPMENT ORDINANCE. WHEREAS, city staff of the City of Woodburn has prepared an outline of the issues to be addressed in the update of the Woodburn Development Ordinance (WDO) in Exhibit "A" at the direction of the Woodburn City Council; and WHEREAS, city staff of the City of Woodburn is directed by the City Council to prepare draft revisions ofthe WDO to address the issues outlined in Exhibit "A"; and WHEREAS, Section 4.101.17 of the Woodburn Development Ordinance requires the City Council to initiate the legislative amendment process by resolution; NOW THEREFORE: THE CITY OF WOODBURN RESOLVES AS FOLLOWS: Section 1. Pursuant to Woodburn Development Ordinance Section 4.101.17, the annual review of the Woodburn Development Ordinance is initiated and staff is directed to prepare draft revisions to the WDO to address the issues outlined in Exhibit "A." APprovedastoForm?7(Yq-~ /2- 'I-ZoO:! City Attorney Date / /' Passed by the Council December 8, 2003 Submitted to the Mayor December 10, 2003 Approved by the Mayor December 10, 2003 Filed in the Office of the Recorder December 10, 2003 ATTEST 1Y1~--r~ I Mary~nnant, City Recorder Page 1 - COUNCIL BILL NO. 2489 RESOLUTION NO. 1745 Exhibit U A" WOO UPDATE CODE LOCATION Section 1.101.06, Page 1.1-2 1.104.04, Pages 1.1-23 & 24 Section 1.1 1-20 Section 2.203.15, Pages 2.2-16 to 22 1.7, Page 2.1-26 Table 2 .......w..~ This provision is fairly common in zoning ordinances but may create legal problems. Home owners in the CG zone have not been able to refinance their homes because the WOO specifies that non-conforming single family dwellings cannot be rebuilt in the CG zone. Amend the code so that a change or expansion of an existing use triggers the wall and refuse facilities requirements in the code. Allow the RIS zone to have the same lot coverage standard as the Single Family Residential (RS) zone. Mayor Figley proposes that this issue be addressed. Ensure that changes in state law regarding Manufactured Dwelling Parks are accurately reflected in the WOO. A single family dwelling currently has to meet the same setback requirements as a multifamily building in the Medium Density Residential (RM) zone. Staff are recommending that the RM zone PItOPOSED POLtCYCHAI 1. Section 1.101.06 regarding improper 1-24 04.05, Page Section be deleted (CG) 2. Allow non-conforming single family dwellings in the Commercial General zone to be rebuilt if destroyed. permits being void should 04.05 to include walls and refuse facilities. 3. Amend Section 1.1 103.07.G, Page 2 Section 2 4. Amend lot coverage in the Retirement Community Single Family Residential (RIS) Zone to allow a maximum of 40% for lots containing a primary building with an average height of 14 feet or less, and a maximum of 35% for lots with a primary building with an average height of more than 14 feet. 5. Allow for exceptions to the front yard setback for small structures (Le. - trellises, arbors, pergolas and archways). 6. Update Manufactured Dwelling Park standards to state law. with them consistent make 7. Table 2.1.7 requires a minimum 24 foot, 30 foot and 36 foot interior yard setbacks for single and two family dwellings. This should be revised to apply RS standards to these uses. PAGE WDO UPDATE WOO UPDATE Section 2.105.05.C.1.a.2, Page 2.1-35 & Section 2.106.05.C.1.a.2, Page 2.1-45 18 Page 2.1-51 1-53 Section 2.201.03.8. Page 2.2-2 Section 3.1 Pages 3.1-17 & E.1, L.3, Page 2 04.01 107.01 1 07.Q1 Section 2 Section 2 be revised so that the single family dwelling setback standards in the RS zone apply to single family dwellings in the RM zone. Staff would like more flexibility in applying the 150 foot maximum yard setback based on the size and shape of a commercial lot and the existing buildings on a commercial site. Check cashing and pawnshops were outright permitted in the CG zone in the WZO. Check cashing and pawnshops are conditional uses in the CG zone in the WOO. Was this provision supposed to be changed with the adoption of the WOO? The Woodburn Zoning Ordinance prohibited bars and taverns in the DOC district. Bars and taverns are allowed in the DOC district per the WOO. Was this provision supposed to be changed with the adoption of the WOO? Address the issue of reducing the setback of a fence on the side and rear of a lot that abuts a street if the vision clearance standards are met. In two appellate court decisions it was found that the nexus did not 8. Move the provision in the commercial zones that the maximum yard abutting a street shall be 150 feet to the architectural guidelines section of the WOO where this provision would be a .should." 9. Clarify what the finance and insurance use mean because it is not clear. Also. all zones prohibit check cashing, pawnshops, etc. except in the CG zone where it is a conditional use. Was this intended? 10. Prohibit bars and taverns in the DOC district. 11. Revise fence height on a corner and through lot (side and rear yard abutting a street). Amend the fence and freestanding walls section of the code to clarify that the setback of fences and walls applies only to front yards adjacent to a street and not any lot line adjacent to a street. 12. Remove the requirement that property line adjustments be subject to the access .Q..ermit requirement and link the access section to the street section of the PAGE 2 woo UPDATE WOO UPDATE Section 3.104.01, Pages 3.1-17 Section 3.104.02. Page 3.1-18 PAGE 3 exist between a street improvement and a property line adjustment. There is not a link in the access section to the street section of the WDO. A building permit for a single family dwelling, administrative design review request and a partition request are examples of Type I and II applications. These types of applications currently trigger the public hearing process through an exception or variance application if the dedication of the full right of way and street improvements cannot be met. Staff is proposing that exception and variance requests be processed through the administrative decision making process if these applications are processed concurrently with a Type I or Type II application because the application fee and time required to process the exception or variance request is reduced if it is an administrative process. A 24 foot wide drive-through and by-pass lane is wider than what is necessary. It is difficult for an applicant to meet the 24 foot wide drive-through and by-pass lane WDO. 13. Change the Exception and Variance Type III application for the dedication of right of way and street improvements to a Type II application if it is processed concurrently with a Type I or II application. 14. Reduce the 24 foot by-pass lane width for a drive-through. WDO UPDATE WOO UPDATE Section 3.105, Pages 3.1-27 to 36 Table 3.1.4, Page 3.1-36 1-39 Page 3 1 Section 3.106.03.C Section 3.106.04, Page 3.1-40 Section 3.107, Pages 3.1-43 to 66 B.S. Page 3.1-67 Section 4.102, Page 4.1-24 video rental business operates more like a retail use than an office use. Code needs to be revised to reflect this. Need direction in the code regarding this problem. The compact parking stall width needs to be changed to accurately reflect a compact parking stall width. Address the issue of requiring parking lot landscaping for uses in the P/SP zone as is required in the commercial and industrial zones. Address the issues of how to amend conditions of approval to save a significant tree and creating a tree mitigation fund or give the replacement trees to the City to plant. Address the issue of removing non- livable spaces in single family dwellings from the window calculation requirement. Currently, the WOO does not have a provision that would allow staff to require a masonry wall on a subdivision where lots have frontage on a non-local street. Have legal staff propose changes when a use doesn't fit in a feet to 7.5 feet to match the 19. Parking section needs to state what happens specific parking category. 20. Change the compact parking stall width from 9 7.5 curb length for the 90 degree aisle. Add parking lot landscaping standard for the P/SP zone. 21 22. Revise Conservation of Significant Tree section of the WOO in regard to tree mitigation fund and how to amend conditions of approval to save a significant tree. Section 3.108.01 23. Refine Architectural Standards. Section 3.107.03 (F) should be modified to read: "At least 15 percent of the fa~e wall surface. excluding roofs and the triangular wall area under a gable roof, and the garage faltBde of a dwelling unit facing a front lot line shall be windows.. 24. Add under the buffer wall requirement that a masonry wall should be constructed on single family subdivisions where lots have frontage on a non-local street. 25. Consider revising Section 4.102 in regard to appeals based upon our PAGE 5 WDO UPDATE WOO UPDATE Page 5.1-18 Section 2.1 02.06.C.b.1, Page 2.1-9 (RS Zone), Section 2.103.06.C.1.b.1, Page 2.1-17 (RIS Zone), Section 2.104.06.C.1.b.1, Page 2.1-25 (RM Zone), Section 2.105.05.C.1.b.1, Page 2.1-35, (CO Zone), Section 2.1 06.05.C.1.b.1, Page 2.1-45 (CG Zone), Section 2.109.06.C.1.b.1, Page 2.1-62 (IP Zone), Section 2.110.06.C.1.b.1, Page 2.1-70 (IL Zone), & Section 2.111.05.C.1.b.1, Page 2.1-77 (P/SP zone) 1-21 &2 Section 5.102.05, Page 5 Section 5.1 02.02.A.1 after receiving input from staff. It is unclear if an expansion over 1,000 square feet would trigger an administrative design review request because they are adding less than 10% of gross floor area of the existing building. Council direction to clarify. Should storage and display be more clearly addressed in the allowed use sections of zones? Address the issue of whether a parking setback is needed from a wall. experience with this section. 26. Clarify Section 5.1 02.02.A.1 &2 regarding the trigger for an administrative design review request. 27. Get policy direction on how Residential Architectural Standard Substitution should be interpreted. 28. Clarify how storage and display are addressed. 29. Revise code to allow parking in a required setback adjacent to a wal PAGE 6 Should parking be allowed on the rear of a through lot? Currently no parking is allowed in the 20 foot setback on the rear of a through lot adjacent to a street. Should a property owner be allowed to have more useable space on the rear of 30. Address setbacks and parking on a through lot. WDO UPDATE WOO UPDATE Section 5.101.04.0.2, Pages 5.1-4 & 5 Section 5.101.05.0, Pages 5.1-6 to 8, Section 5.101.06.0, Pages 5.1-9 to 11, Section 5.101.07.0.1, Page 5.1-12, Section 5.101.09.0, Page 5.1-14 a through lot? Need to clarify what is being certified by various officials. 31. Clarify the certification process related to review of plats & covenants for Manufactured Dwelling Park Final Plan Approval, Partition Final Plan Approval Planned Unit Development Final Plan Approval, Property Line Adjustment/Consolidation of Lots and Subdivision Final Plat Approval Need to add a provision in the WOO to regulate portable toilets since portable toilets are no longer regulated by the City's Nuisance Ordinance. Address grading permit in the WDO to strengthen criteria. Address transportation impacts of development. Address the issue of businesses not allowing competitors to buy or lease their big box stores. 32. Add Portable Toilet provision to the WDO. 33. Grading Permit would not be allowed to exclude 34. Concurrency 35. If a big box store is vacated, then it competitors as a condition of approval 1-2 lots. lanes. 1. 2. 3. 4. 5. 3 to 27 Pages 6.104-1 04 Section 6.1 to be made In the Health Care and 6. Check and revise Use Classifications in the WDO. Corrections need Social Services (62) table. PAGE 7 WDO UPDATE WDO UPDATE 7. It would be beneficial to show a curvilinear lot and how it would be determined to be an interior or comer Figure 6.2, Page 6.102-2 lot. 8. Stall depth (F) is not shown in Figure 6.10. Correct mistakes in the diagram. Figure 6.10, Page 6.102-10 1. In regard to the definition of Mobile Food Services, replace "Section 2.203.16" 2. Add "attached" after "Figure 6.6 and Section 3.104.0S" 3. Delete "banks" after "use" 4. Replace "71391" with "71394" S. "Definitions" should not be repeated twice. 6. Delete "commercial" after "from" and before "or" 7. Replace "abutting street(s)" with "connecting street(s)" after "and" and before "are" 8. Insert "that" between "lots" and "are" 9. Replace "Exist" with "Exit" 10. Change"f' to "6" 11. Delete "Partition and Subdivision Standards (See Figure 6.11)" 12. Insert "be" after "may" and before "flexible" 13. Exception to Street Right of Way and Improvement Requirements is a Type III decision and not a Type decision. 14. Residential Architectural Standards Substitution is a Type II and not a Type I decision. 1S. Delete "statement" after "narrative" and before "statement" 16. "S.1 02.103" should be "S. 1 02, 5.103 and S.1 04" 17. Insert "initial evidentiary" after "all" and before "public hearings. and after "Type III" and before "hearing Replace "City" with "Director" after "the" and before "shall." Insert "initial evidentiary" after "the" and before "hearing". 18. Delete "to" and "a" after "before" and before "public hearing." Insert "an initial evidentiary" after "before" and before "-ublic hearina." Delete "Community DeveloDment" after "the" and before "Director". 17" Section 2.203. with 13 Table 4.1, Section 4. Section 4. Section 4. Section 4.101.09.A.3, Pages 4.1-13 PAGE 8 WDO UPDATE WOO UPDATE 19. Delete "a" before "public" and after "of." Insert "an initial evidentiary" after "or and before "public hearing" Section 4.101.09.8, Page 4.1-14 20. Insert "or review" after "all" and before "hearings." Delete "i" in "parities" after "other" and before "shall." Section 4.101.12, Page 4.1-19 Insert an "s" at the end of "call" after Council and before "a." Add a period at the end of the second to the last sentence after "allow" and before "The." Delete "persons" after "record" and before "applicable". 21. Delete "nof after "has" and before "been" Section 4.102.03, Page 4.1-26 22. Remove .01 at the end of Section 3.107.01 Section 5.101.D, Page 5.1-2 23. Insert "not" after "are" and before "limited" Section 5.102.03.C.2, Paae 5.1-19 24. Insert "a" before "special" and after "be" Section 5.103.04.C.1, Page 5.1-27 25. Remove "a" before "formal" and after "a" Section 5.104.03, Page 5.1-44 PAGE 9 1:\Communlty Development\Planning\WDO Update\WDO Update4.doc 12/03/03 WDO UPDATE