Loading...
Agenda - 10/31/2005 WOODBURN CITY COUNCIL SPECIAL MEETING AGENDA OCTOBER 31, 2005 - 7:00 P.M. 1. CALL TO ORDER AND FLAG SALUTE 2. ROLL CALL 3. GENERAL BUSINESS - Members of the public wishing to comment on items of general business must complete and submit a speaker's card to the City Recorder prior to commencing this portion of the Council's agenda. Comment time may be limited by Mayoral prerogative. A. Council Bill 2596 - Ordinance to complete Periodic Review work tasks by amending the Woodburn Comprehensive Plan; adopting a new Urban Growth Boundary; amending the Woodburn Development Ordinance; repealing Ordinance 1689; adopting certain background documents; making legislative findings; and setting an effective date Recommended Action: Adopt the ordinance. 4. ADJOURNMENT UH<lbr~ interpretes qisponibles p<lt"<l <lquel[<ls person<ls que no h<lbl<ln Ingles, previa <lcuerqo. ComunTquese <ll (503) 980-2485.** October 31, 2005 City Council Special Meeting Agenda Page i "1"'!' r MEETING NOTICE L KATHRYN FIGLEY, THE DULY ELECTED MAYOR OF THE CITY OF WOODBURN DO HEREBY CALL A SPECIAL MEETING OF THE WOODBURN CITY COUNCIL. TO BE HELD ON MONDAY, OCTOBER 31, 2005, AT 7:00 P.M. IN THE WOODBURN CITY HALL COUNCIL CHAMBERS, 270 MONTGOMERY STREET, WOODBURN, OREGON TO CONSIDER ADOPTING THE CITY'S PERIODIC REVIEW WORK PROGRAM. THIS MEETING IS CALLED PURSUANT TO THE WOODBURN CITY CHARTER AT THE REQUEST OF THE MAYOR. DATED THIS 19TH DAY OF OCTOBER 2005. - ..... n, ;\ ~~..~~.:.t4r.. 'J;r ..... . . WQ.QD~tL~N Ilt(o(I'~'raled -/889 ~~ . . October 31 , 2005 TO: Honorable Mayor and City Council FROM: John C. Brown, City Administrator N. Robert Shields, City Attorney Greg Winterowd, Planning Consultant SUBJECT: Additional Periodic Review Materials Legislative Amendment 05-01 RECOMMENDATION: Receive the additional materials and adopt the ordinance. BACKGROUND/DISCUSSION: Several days ago, the City Council was provided an ordinance, with attachments, to be considered at the October 31, 2005 special meeting. Since that time, minor changes have been made to a limited number of documents, which are summarized below and reflected in the attached materials: . An updated "Appendix C" was added to the Public Facilities Plan (Exhibit 1-B of the ordinance). The updated appendix is attached. . Minor revisions were made to details contained in both the Findings of Fact (Exhibit 5-A) and the UGB Justification Report (Exhibit 5-B). For instance, Crosby Road was inaccurately referenced as an "arterial street" when it is actually a "service collector." The necessary corrections were made. In addition, minor language changes were made to the ordinance. Also, Attachment 5-D (containing certain staff reports that are already in the record) is no longer incorporated into the ordinance. The attached copy constitutes the final form of ordinance. Attachments: Ordinance Appendix C to Public Facilities Plan Agenda Item Review: City Administra City Attorney Finance l' 11 T ~/' , - :th": \ ,.. 00.;: , _' r' . -.. . .'fiT ...... .' WQ.Q.DBQ.~N In'o'J'~"a"J 'llS'! ~~ . . October 31 , 2005 TO: Honorable Mayor and City Council FROM: John C. Brown, City Administrator N. Robert Shields, City Attorney Greg Winterowd, Planning Consultant SUBJECT: Additional Periodic Review Materials Legislative Amendment 05-01 RECOMMENDATION: Receive the additional materials and adopt the ordinance. BACKGROUND/DISCUSSION: Several days ago, the City Council was provided an ordinance, with attachments, to be considered at the October 31, 2005 special meeting. Since that time, minor changes have been made to a limited number of documents, which are summarized below and reflected in the attached materials: . An updated "Appendix C" was added to the Public Facilities Plan (Exhibit 1-B of the ordinance). The updated appendix is attached. . Minor revisions were made to details contained in both the Findings of Fact (Exhibit 5-A) and the UGB Justification Report (Exhibit 5-B). For instance, Crosby Road was inaccurately referenced as an "arterial street" when it is actually a "service collector." The necessary corrections were made. In addition, minor language changes were made to the ordinance. Also, Attachment 5-D (containing certain staff reports that are already in the record) is no longer incorporated into the ordinance. The attached copy constitutes the final form of ordinance. Attachments: Ordinance Appendix C to Public Facilities Plan Agenda Item Review: City Administra City Attorney Finance l~ rn MethodoloQY for Calculations - Urban Growth Boundary Expansion City of Woodburn - Public Works Department April 2005 1. Public Works provided assistance to Community Development (Comm. Dev) in preparation of estimated costs for infrastructure related to proposed expansion of Urban Growth Boundary. 2. Comm. Dev determined 8 subareas for expansion. Public Works was provided mapped limits for the subareas and proposed land use designation within each of the areas. 3. Land use categories were as Residential, Commercial, and Industrial. Combinations were devised by application of formulas, without describing the location within a mapped area where any particular land use might occur. 4. Public Works was charged with estimating costs for water, storm sewer, and sanitary sewer within the boundary of each of the 8 subareas. 5. The physical size (in acres), of each land use for each subarea was calculated using CAD. 6. Master Plan criteria for water consumption, sanitary sewer flow rates and storm water runoff were used to determine values for each land use. Sizes of conveyance facilities were calculated for all areas by uniformly applying derived flow rates. Conceptual grid patterns for distribution pipes, sewer collection lines, and storm water collection lines were devised. The conceptual patterns were extrapolated and reduced to formulas for costs to serve on an acreage basis. Generally, the delivery of service to each sub area was considered to occur at one Point of Connection. This simplification did not consider market-driven development factors that would likely produce need for a greater number of connection points in the future, depending on the geographical extent and location of demand. 7. Based on CIP cost records (maintained by Engineering staff) and System Development Charges from Comm. Dev Planning staff, a cost per acre for each land use type was derived and are as follows; Water Systems: Residential = $9.0KlAC Comm.llndustrial = $5.1 K1AC Sanitary Sewer: Residential = $10.8K1AC Comm.llndustrial = $5.0KlAC Storm Sewer: Residential = $7.8K1AC Comm.llndustrial = $3.6K1AC .... "'" ...... 8. Flow rates for these three infrastructure systems are as follows; Water Svstem Residential = 1,315 gpd/AC (Avg.), 5,130 gpd/AC (Max.), 120,000 g/2hr. Commercial/Industrial = 382 gpd/AC (Avg.), 1,490 gpd/AC (Max.), 600,000 g/2hr. Sanitary Sewer Residential = 1,420 gpd/AC Commercial/Industrial = 700 gpd/AC Storm Sewer All areas: 0.5 cubic feet per second (cfs) per acre This empirical value was applied uniformly, regardless of projected land use, because little difference was discemable between runoff factors in conditions of a design storm. Discharge from subareas larger than 150 acres were analyzed as Primary Drainage ways, in accordance with definitions from the Storm Drainage Master Plan (SDMP). Areas greater than 50, but less than 150 acres were described as Secondary Drainage ways. The SDMP instructs that conveyance systems for Primary Drainage ways accommodate runoff from 100-year event. Secondary Drainage ways are designed for 50-year events. The sizes of pipes were determined based upon their estimated slope and approximate design runoff for the tributary subarea. 9. The estimates considered that planning has already been made for some major infrastructure projects (mostly within the current Service Areas, and shown in a five-year plan called Capital Improvement Program, or "CIP"). Calculations were performed assuming that water, sanitary sewer, and storm drainage Capital Improvement Projects shown in the budget for fiscal year 2004-20005 were accomplished before any of these expansion projects were under taken. 10. Some infrastructure elements within the existing UGB would need upgrading to serve individual expansion subareas. Some of these improvements were not included in the CIP. Where additional improvements were necessary to existing systems situated within the existing service limits, the cost of improvements was estimated by application of historic construction cost records. These costs were added to other cost elements related to provision of service within each subarea. Included were water booster stations and sanitary sewer pump stations whose locations and sizes are shown on work maps that were prepared in course of the work. ..,.. '"' .,... REGION No.1 GENERAL: . Approximately 655 AC total areas. For evaluation purposes, this region was divided into 360 AC of Residential and 240 AC of CommerciaVIndustrial, 55 acres have been excluded from the total for flood plain riparian areas. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system can be looped to the adjacent existing system without requiring any additional distribution line between systems. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (2.93 MGD). . Estimated cost of construction of distribution infrastructure is $4.48 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . This region would be expected to require construction of a new lift station in the Northern most point at an estimated cost of $600,000. . The new lift station would then require a new gravity line to Boones Ferry Road at an estimated cost of $400,000. . Estimated new collections systems cost is $5.10 million and will generate an approximate load of 1.05 cfs. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage appears adequate to handle outfall(s) to both fingers of Senecal Cr. to service this area, approximate 300 cfs. . Estimated new collections systems cost is $4.17 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $4,480,000 $6,100,000 $4.170.000 $14,750,000 REGION No.2 Revisions, July 01, 2005 " T!I i GENERAL: . Approximately 675 AC total area. For evaluation purposes this region was divided into 440 AC of Residential and 210 AC of CommerciallIndustrial. 25 acres have been excluded from the total for flood plain riparian areas. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system will require extension of the existing distribution system by approximately 1300LF of 12-inch dia. main looped to the adjacent existing system at a cost of $180,000. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (3.3 MGD). . Estimated cost of construction of distribution infrastructure is $5.02 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . This region would require construction of a new gravity system to connect to the existing system at the North end of Boones Ferry Rd and/or the Mill Creek Interceptor. . From the Boones Ferry Rd. connection point, approximately 4000 LF of collector will have to upsized to the Goose Cr. connection of the parallel westerly reliever at a cost of $500,000. . Estimated new collections systems cost is $5.78 million and will generate an approximate load of 1.19 cfs . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage appears adequate to handle outfall(s) to upper Mill Cr. to service this area, approximately 325 cfs. . Estimated new collections systems cost is $4.17 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $ 5,200,000 $ 6,280,000 $ 4.170.000 $15,650,000 Revisions, July 01, 2005 nr T REGION No.3 GENERAL: . Approximately 330 AC total area. For evaluation purposes this region was divided into 100 AC of Residential and 230 AC ofCommercialJIndustrial. . Flow rates for water; sewer and stonn distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system will require extension of the existing distribution system by approximately 400LF of 12-inch dia. main looped to the adjacent existing system at a cost of $60,000. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (1.6 MOD). . Estimated cost of construction of distribution infrastructure is $2.09 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . This region would require construction of a new gravity system to connect to the existing system at Industrial Pump Station on Industrial Way. . From the connection point, approximately 1200 LF of collector will have to upsized to the Industrial Way Pump Station at a cost of $265, 000. . Estimated new collections systems cost is $2.25 million and will generate an approximate load' of 0.5 cfs. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage is adequate to handle outfall of only a small portion to upper Mill Cr. The bulk of the region would require construction of approximately 1400 LF of 78-inch dia. pipeline Easterly to natural tributary to the Pudding River at a cost of $521,000, approximately 167 cfs. . Estimated new collections systems cost is $1.62 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $ 2,150,000 $ 2,515,000 $ 2.141.000 $ 6,806,000 Revisions, July 01, 2005 r m- T REGION No.4 GENERAL: . Approximately 343 AC total area. For evaluation purposes this regIon was determined to be all Residential and no Commercial/Industrial. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system will require extension of the existing distribution system by approximately 1l00LF of 12-inch dia. main looped to the adjacent existing system at a cost of $154,000. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (1.88 MGD). . Estimated cost of construction of distribution infrastructure is $3.1 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . This region would require construction of a new lift station, off Hwy. 211 then a 5000 LF of force main to the WWTP at a cost of $1.5 million. . Estimated new collections systems cost is $3.70 million and will generate an approximate load of 0.75 cfs. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage is inadequate to handle outfall. Runoff would, therefore, require construction of approximately 2000 LF of 78-inch dia. pipeline Easterly to the Pudding River at a cost of $745,000, approximately 170 cfs. . Estimated new collections systems cost is $2.68 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $ 3,254,000 $ 5,200,000 $ 3,425.000 $11,879,000 Revisions, July 01, 2005 TIT .,... REGION No.5 GENERAL: . Approximately 431 AC total area. For evaluation purposes this region was assigned into 431 AC of Commercial/Industrial and no Residential. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system will require extension of the existing distribution system by approximately 3600LF of 12-inch dia. main looped at a cost of $500,000. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (1.24 MGD). . Estimated cost of construction of distribution infrastructure is $2.20 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . This region will require construction of a new lift station in the Northwest comer of the region at an estimated cost of $350,000. . The new lift station would then require a new force main of approximately 4800 LF to connect to the existing gravity collection system at the Mill Cr. trunk line off of Cleveland St. at an estimated cost of $750,000. . Estimated new collections systems cost is $2.16 million and will generate an approximate load of 0.50 cfs. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage is inadequate to handle outfall. Runoff, therefore, requires construction of approximately 4500 LF of 84-inch dia. pipeline Easterly to the Pudding River at a cost of $2.0 million, approximately 216 cfs. . Estimated new collections systems cost is $1.55 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. Cost Estimate Summary: Water Improvements Sanitary Sewer Storm Sewer Total $ 2,700,000 $ 3,260,000 $ 3.150.000 $ 9,110,000 Revisions, July 01, 2005 l' m T REGION No.6 GENERAL: . Approximately 191AC total area. For evaluation purposes this region was assigned into 189 AC of Residential and no CommerciallIndustrial, 2 acres have been excluded from the total for flood plain riparian areas. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system will require extension of the existing distribution system by approximately 5000LF of 12-inch dia. main looped at a cost of $600,000. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (1.09 MGD). . Estimated cost of construction of distribution infrastructure is $1.7 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANIT MY SEWER SYSTEM: . This region will require construction of a new lift station along the Southerly fmger of Mill Cr. and behind Shalimar trailer park at a cost of $350,000. . The new lift station would then require a new force main of approximately 1800 LF to connect to the existing gravity collection system at Bridlewood Ln. and Brown St. at an estimated cost of $250,000. . Estimated new collections systems cost is $2.04 million and will generate an approximate load of 0.40 cfs. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage appears adequate to handle outfall(s) to South Mill Cr. to service this area, approximately 95 cfs. . Estimated new collections systems cost is $1.47 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $ 2,300,000 $ 2,640,000 $ 1.470.000 $ 6,410,000 Revisions, July 01, 2005 1< 1" T REGION No.7 GENERAL: . Approximately 510 AC total area. For evaluation purposes this region was divided into 380 AC of Residential and 130 AC ofCommercia1/Industrial. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system will require extension of the existing distribution system by approximately 6100 LF of 12-inch dia. main looped at a cost of $700,000. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (2.87 MGD). . Estimated cost of construction of distribution infrastructure is $4.1 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . This region will require construction of 1000 LF of new gravity sewer line to connect to the existing system at the South end of Harvard St. at a cost of $80,000. . The existing gravity collection system at Harvard St. would require being up sized for approximately 3300 LF to 1-5 pump station at an estimated cost of $250,000. . Estimated new collections systems cost is $4.77 million and will generate an approximate load of 1.0 cfs. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . A new collection system would connect to the existing system on the West end of Parr Rd. and require upsizing the existing collector to a 84-inch dia. line at a cost of $1.7 Million, approximately 255 cfs. . Estimated new collections systems cost is $3.44 million. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $ 4,790,000 $ 5,100,000 $ 5.140.000 $15,030,000 Revisions, July 01, 2005 ... REGION No.8 GENERAL: . Approximately 755 AC total area. For evaluation purposes this region was divided into 457 AC of Residential and 298 AC of Commercial/Industrial. . Flow rates for water; sewer and storm distribution and collection systems are based on zoning densities appropriate to the assigned land use and Master Plan consumption/contribution rates. . When and where practical topographic geography was considered in gravity systems. . This region was analyzed independent of other proposed regions. . The analysis is based on all CIP projects, identified in the current Master Plan Documents, have been completed. WATER DISTRIBUTION SYSTEM: . A new distribution system can be looped to the adjacent existing system without requiring any additional distribution line between systems. . Flow rates were based upon Master Plan use rates per capita and 2-hour fire durations (3.5 MGD). . Estimated cost of construction of distribution infrastructure is $5.62 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. SANITARY SEWER SYSTEM: . A new collection system would connect to the existing system on the West end of S. Woodland Ave. flowing to 1-5 pump station. . Existing collector would require upsizing to a 24-inch dia. line at a cost of $250,00. . Estimated new collections systems cost is $6.42 million and will generate an approximate load of 1.32 cfs. . Analysis indicates the existing system (Le. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. STORM SEWER SYSTEM: . Natural drainage appears adequate to handle outfall(s) to both fingers of Senecal Cr. to service this area. Approximately 375 cfs. . Estimated new collections systems cost is $4.63 million. . Analysis indicates the existing system (i.e. current 2004 service area) will support the improvements, estimated costs are shown below in the summary. COST ESTIMATE SUMMARY: Water Improvements Sanitary Sewer Storm Sewer Total $5,620,000 $6,670,000 $4.630.000 $16,920,000 Revisions, July 01, 2005 ..,~" T I/) - o w II) <( w ~ o ~ en C) ::::) ~ o LL en ... z w ::E .w O:~ <(- .::::) ena w ~ ~ w ... ~ LL o Z o i= <( ::::) ..J <( > W IJ .0 D- ctCLL. I-cl:!:: O:E~ t- ~ -IcO- <tZ...JU) t-'LL.a: o:EUJ::t: 1-8~~ LL. ~ -I 0- <tU)...J~ I-WLL.::t: oa:WN I- a:_ iL U ~::E ~ _:;) "Cl a:::Ec~ I--Q~ (1)>< . ::>><1: ~ c:::iE ~ Z ..... 5 <( ow u a:o ~ Wc{ci5. :EO::cc>> :EW ~ 0><( ~ o ~ U :E ~ ic"R. ...J~c~ <c"" ~ 1-... .... ffi II) o u Ujw ~ wo c a:~c~ wO... > . < ~ l") ..... Ow zo ,< :Ew :Ea: 00 0< (1)0 ~< mmom......COOv mmvlO("')OCO<O OvlO<om<o("')("') ('f) I/f ...: ai ...: ai c:S 1.0- ("') I'--COI'--V CO 1'--0 mNIOCONOCOIO N('f)"':"':"':":N('f) I'--NO ::;:; ("')N<o <O(",)N a; vco m ..... 1.0_ 0 ..: 0 <0. 0 I/fcxico V Ov ~m~ N_ ~o ...... ..... NI'--om ~leN~ ~cD~aio .....1.0("')1'-- m. ("'). <0 co. ......N ..... CO <0"'" 0("')0 <01'--1.0 ai m. -.i co I'-- <0 oov ....... N N. I'--NO (",)N <O(",)N ("') v<O m. 1'--. 1.0. 0 m. 0 co. co. 1.0 co co ..... 00 IO.....V V mv (\')("')("') <0 .....v lO.....m N I.OV m<ov 0 01'-- m N 0 0 1'--_0 co...... N('f)": ~ ai~ mcom ..... v...... N.....om coco...... ~leN~ 0~f5 ~ cO 0_ ai 0 co. ai -.i 1.0("')("')1.0 mlOv CON........... COm(\') - -1.0 - m . . "r""""N..... "I""""N I.OvON ......MCO l'--......vCO ......COM .....1.01.0..... <ov..... cDcri":":OcxiN": I'--.....MI.O vOO vlO.....V NIOCO mvv ...... CO<O M.....MOMONm NNN v .....N N<OOM mNI'-- <OMOVOCOCOI.O MV......M .....Mv tLW OZ a:O tLN .....N(\')VI.O<OI'--CO m ..... o ..... I'-- M co. ..... 1.0 1.0 <0 cD m CO I/f V N v o co v N ..... 1.0 1.0 CO 8 N N cD CI <G .... o - III (!) ::E .. o~ ~D- - ..... COo ..... .. ..c::('I) 01/) ....0 a10 ~~ ...:~ ~o ........ CD CD 't;j't;j 00 _ '0 aI CD c- ._ c C) 'c 'C D- O N m m ai m 1.0 ..... <Ci -c c <G o (!) ::E co d ..... - o o :J -c o .... 0.. CD :a "0 :J -c o .... 0.. CD > IV .r:. V N V o v <0 ..... ..... M V <0 -.i co m N .~ ~ 1.0 - :J o :!2 "5 .c a. ~ - o m co N N CD III IV .r:. a. a ~ o '7 II) :) en W I- o Z r 1'1 T I.() - o /~ Jj <Q 0.. zo -oct -noW _UJ~ a~tI) mo Z o (5 UJ a: > m U) UJ a: ct Z ::) o m o UJ o Z UJ l- X UJ LL o U) ii) > ...J c( Z c( I- m o o z ~ o 2 a: o I- m a I- o I- o aZI- I-:::::U) 020 1-00 o a a!zl- I-UJU) OcO 1-ii)0 w a: ~t; :::::00:0 20UJc( 000. om ...J ~t; zOO:o ~oUJc( -co. ~m a: CUJ zc) i~ :!EO: 8~ ~1Ot-~~IOIO~ ONCO.....IO~IOCO g('l').....~NO)N~ 00000000 00000000 00000000 00000000 ONvvCONvN v.~NIO.~~cici CIOt-Nt-IOt-V('l') CO.....COCOIOVVCO c<i~~N~~c<i~ CItCltCltCltCltCltCltClt 000 0 00 000 ~ o~ 00008008 oooocooOco V.V.V.o ......0 CIO.1ii ~R~CIt:gClt~~ CIOt-CIO - v . CltCltfl't ;; CIt;; 0000 000 ~~o~ ~~~ 00.0 000 000000000 co. CIO. 0 v. ~ N. co. co. ('I')OO.IOOVO)V NOcot-fl'tt-t-CO co. v. t- co. v. 0). 10. ~~fI't~ E4~~ 00000000 00000000 00000000 00000000 CO co co coco co coco ('1'). c<i ('1'). c<i c<i c<i c<i c<i fl'tCltCltCltfl'tfl'tCltClt 00000000 00000000 oc:ic:ioc:ic:ioo 00000000 CIOCIOCIOCOClOCIOCIOCO r-: r-: r-: 1'-. r-: r-: r-: r-: fl'tfl'tCltCltfl'tfl'tCltClt ~~~0C;;0~~ NNN v .....N mo ~<C NCOO('l') o)NI'- CO ('I') 0 vOClO CIOIO ('I')v.....('I') .....('I')v Q.UJ OZ 0:0 Q.N .....N('I')VIOCOt-CO o o o o v 0). v N c<i N CIt o o o o N ""It o~ ~o.. - 1"'"' CIOo ..... "" C") ~~ asO ::!~ ":<"1 .Eo ~..... 0).$ -as (30 _ "'C as 0) c- .- C 01 "C "C 0.. o ..... 10 10 Iii fI't o o o o N CIO. 0) co r-: ..... fI't N v 10 ~ o .... en :E a. .~ 0::: U o (j) c:: o Q. ::J "C Q) en (Q .Q Q) Iii Q) o (Q .... Q) Q. - en o U Ui I- a z 0) co N N c o Jo;- ID ~ en r 1.1) - o .-..., Jl aJ a.. 2 o (5 w 0:: >- In en w ~ ~ o 2 :;) o In o W o 2 W ~ )( W LL. o en Ui >- ..J ~ 2 ~ ~ en o u 0:: w ~ en ~ ~ ~ Z ~ en ~ o ~ o cl2~ ~=::::en O:EO ~Ou u cl cl!z~ ~Wen OCO ~Uiu W 0:: ~t; =::::OO::U :EOW~ 000.. om ~t; ZOO::O ~UW<( _co.. fflen 0:: Cw 2C) =::::~ :Ew :EO:: 00 U<( rnu It:!~ o..w 02 0::0 D..N 00000000 00000000 cicicicicicicici 00000000 COClOovONCOCO ~ ai 0 v. \l'i ~ \l'i \l'i Or--lOOlOvCO~ ~r--Nr--~Or--v .o.oN('t)NN~rD ~~EflEfl~~EflEfl 000 0 00 ~~~ ~ O~ 000 0 .0 00000080 o_o_~~ o.~ 0 O. lOOOOlOOO'O mr--r--fltlOfIt_ClO ~.~~. .... <ov. ...-..-...... N fAo""- Efl Efl fit Efl Efl 0000 000 0000 000 cicioo cicici 00000000 COClOOvONCOCO ai ai 0 ~ ci ~ lO- \l'i OOClOOEflvNM m r-- 0 r-- 0 ~ m ri~~-('t) Nv-~ Efl fit fit fit ~ Efl ~ 00000000 00000000 cicicicicicicici 00000000 00000000 \l'i\l'iICi\l'iICi\l'i\l'i\l'i EflEflfltEflfltEfl~Efl 00000000 00000000 ciciaaaaaa 00000000 ClOClOClOClOClOClOClOClO 00000000 ...-....-..............-..-..-..... fltEflEflfltfltfltEflEfl mvv ..... ClOCO M~MOMONm NNN v ~N NCOOM mNr-- COMOvOClOClOlO Mv~M ~Mv .....NMvlOCOr--ClO o o ci o N ICi ..... N N M ~ o o ci o o o ..... r-- r-: Efl "It o:! ~n. - .... 000 .... .. .s:::.<"'> 01.1) ...0 caO :!~ ":('1.1 .Eo 1-.... Q)$ -ca ~c - "0 ca Q) c=- ._ c= C) 'c . c a.. o o o ci o N \l'i o lO v. N Efl N v lO ~ o 1ii :c a '0 CD a::: () o en c: o a. J "0 CD III l'Il ..c CD .... l'Il CD .... o l'Il .... CD a. m co N N a! t- o '";' aI :::J en - III o () Iii I- a 2 1" l" r Il) "- o A C'll Q.. fIJ u.. (.) z o (; w [t: >- lQ fIJ W i ~ ...J u.. [t: W ~ W fIJ ~ ~ Z <( fIJ >- <i!~g<( 1-00..0 O...JO[t: 1-u..1-~ (.) o ~ ~~UO -0-0.. :E...J~e) Ou.. 0 (.) 0 ,... ~ ~ Z~UO wO-Cl~ O...J .., -u..[t:O rn N w .. [t: .... Ow Ze) :i~ :E[t: 00 0<( flJo ~<( a.w OZ [t:0 a.N 10 o>r-..IOr-..NooN O.......,.r-.....,....,. 0> ('I) "-:"-:00000"-: 00000000 ...,.NOCOOoo...,....,. ('I) 0>00 or-.. ('I) 0.... ""':a:Jllir-:""':a:JN'cD 00 CO 0000 CO ('1)10 COr-..('I)""'('I)NCOoo 000 0 00 000 0 00 ('1)_00_00_01'-_0 CO N r-..m('l) .... or-: co...,.co 0 mO ............ ('I) ooN 0000 ...,.NOCO 0....00 ...,.-ai N'r-: 0 ...........,.00 1.0 CO.......,. 000 00...,....,. ('I)...,.m a:JN'a; CO...,....,. NI.OCO ~~~O(;)O~~ NNN ...,. ....N NCOO('l) mNI'- CO ('I) 0...,. 0 00001.0 ('1)...,.....('1) ....('1)...,. ....N('I)...,.I.OCOr-..oo ~ cO o 00 ('I) ... 0:iE ~n. -~ GOo ~ "" ~(') Oil) ...0 caO ::E~ "':"1 ~C5 ..-...... Q) Q) QiQi 00 - "0 C'll Q) C- .- C Ct "C "C n. o .... o ('I) ~ o o ...,. ai ...... o .... o CD m .... N N cri N ...,. 1.0 .... m CO N N' <it ... o to:' CD :) en n r II') - _0 , , JI cu a.. 2 o a w a: >- fa o w ii: <( o z j o ID o W o 2 W l- X W I&. o o tij >- ..J <( Z <( I- o o o >- ..J 11. 11. j rn a: w i ~ I- o I- o ~21- 1-:::::0 o::EO 1-00 o ~ ~~I- I-W0 000 I-tijO W a: 01- Z0 :::::oa:o ::EOW<( 0011. om ~I- o 201:1:0 ~OW<( -011. fflrn a: Ow 20 i~ ::EI:I: 00 0<( 00 ~<( I1.W 02 a:o o..N 00000000 00000000 00000000 00000000 O)~~O....oco<o <<i ID- ri r-.: <Xi ....- ci N ..........O)COO)OO)N ~ooo..........o<o ~IliNriN...:~1li ~fh~fh~fh~fh 000 0 00 ~~~ ~ o~ 000 0 -0 ~~~g~ggg co- ...: (<)- 0 co- 0 CX). a) ....o)o)~o)fhNo NO.... .... IDID ~~~ ~ ~~ 0000 000 ~~O~ ~~~ 00.0 000 000000000 0_0.0 O_~ 0_0_00 CX) ~ 00...... 0.... CX) (<) IDNOCX)fhO(<)..... N_ 0). 0) 0_ ......0 ~o .....0 ~~fh~ ;;;~~ 00000000 00000000 00000000 00000000 ,....~......-..-,...........- Ili ..0 Ili Ili Ili ..0 ID. Ili fh~fh~fhfhfhfh 00000000 00000000 00000000 00000000 00000000 a) a) a) a) a) 0)0 a) a) fh~~fhfhfhfhfh O)~~ ..... CX)<O (<)......(<)0(<)0 NO) NNN ~ .....N N<OO(<) O)N...... <O(,,)O~Ocx)cx)1D (<)~.....(<) .....(<)~ ......N(<)~ID<O......CX) o o o o N Ili CX) N <Xi N fh o o o o N ~ <0 CX) r-.: fh "It" o;:! ~a.. - .,.... GOo ~~ eo cuO ::!:~ "':N ::20 f=..- Q)~ -cu ~c _ "C CU Q) c= - .- c= C) -c: .C: D- o o o o o o ..... N ~ O. N fh N ~ ID ~ o - II) :c - Q. .0 Q) 0:: U o en c: o Q. ::2 -c Q) II) lU ..c Q) ... lU Q) ... o lU ... Q) Q. - II) o U W I- a z 0) <0 N N ~ I-;' ID :) II) YO 'I'" COUNCIL BILL NO. ORDINANCE NO. AN ORDINANCE TO COMPLETE PERIODIC REVIEW WORK TASKS BY AMENDING THE WOODBURN COMPREHENSIVE PLAN; ADOPTING A NEW URBAN GROWTH BOUNDARY; AMENDING THE WOODBURN DEVELOPMENT ORDINANCE; REPEALING ORDINANCE 1689; ADOPTING CERTAIN BACKGROUND DOCUMENTS; MAKING LEGISLATIVE FINDINGS; AND SETTING AN EFFECTIVE DATE WHEREAS, the City is currently in Periodic Review pursuant to ORS 197.633 and adopts this ordinance to complete certain Periodic Review Work Tasks as specified herein; and WHEREAS, the Department of Land Conservation and Development approved the Work Program for the City on July 30, 1997; and WHEREAS, the City adopted Resolution 1741 initiating amendments to the Woodburn Development Ordinance, the Woodburn Official Zoning Map, and the Woodburn Comprehensive Plan text and map, including functional plans (lithe Periodic Review Amendment Package"); and WHEREAS, the City coordinated with Marion County to develop a 20-year population projection, and Marion County Ordinance 1201, allocated a year 2020 population projection of 34,919 to the City; and WHEREAS, the City used the coordinated population of 34,919 to determine its need for residential land; and WHEREAS, the City considered and accepted the Woodburn Economic Opportunities Analysis and adopted the Woodburn Economic Development Strategy to identify target industrial firms and site suitability needs; and WHEREAS, the City used the Year 2020 population projection and the economic development studies to prepare the Woodburn Public Facilities Plan, the Woodburn Residential Land Needs Analysis, and the Woodburn Transportation System Plan; and WHEREAS, the City sent public notice as required by state law and the Woodburn Development Ordinance; and WHEREAS, the City held open houses to receive public input on the Periodic Review Amendment Package; and Page 1 - COUNCIL BILL NO. ORDINANCE NO. 1 ~ n T WHEREAS, the Woodburn Planning Commission conducted four work sessions to consider the Periodic Review Amendment Package, held a public hearing on February 3, 2005, and recommended approval of the Periodic Review Amendment Package with amendments by the City Council: and WHEREAS, the City Council held a public hearing on March 28, 2005 on the Periodic Review Amendment Package and left the record open until April 20, 2005: and WHEREAS, the City Council deliberated on April 25, 2005 and at its June 13, 2005 meeting, the City Council continued deliberating and allowed additional written testimony to be submitted until June 27,2005 related to four matters: and WHEREAS, the City Council deliberated on September 19, 2005 and tentatively approved the Periodic Review Amendment Package with amendments: and WHEREAS, the passage of this ordinance adopting the amended Periodic Review Amendment Package will complete Periodic Review Work Tasks 1 through 4 and 7 through 11; NOW, THEREFORE, THE CITY OF WOODBURN ORDAINS AS FOLLOWS: Section 1. The Woodburn Comprehensive Plan is amended as provided in Exhibit 1, attached hereto and incorporated herein: including the following sub- exhibits: 1-A Woodburn Economic Development Strateoy (ECONorthwest, June 2001) 1-B City of Woodburn Public Facilities Plan (City of Woodburn, October 2005 ) l-C Woodburn Transportation Svstem Plan (CH2M Hill, October 2005) 1-0 Woodburn Local Wetlands Inventory List (Shapiro, 2000) Section 2. A new Comprehensive Plan Map and urban growth boundary is adopted as depicted in Exhibit 2, attached hereto and incorporated herein. Section 3. The Woodburn Development Ordinance, including the Official Woodburn Zoning Map (2005) is amended as provided in Exhibit 3, attached hereto and incorporated herein. Section 4. Ordinance 1689, the growth management ordinance, is repealed. Page 2 - COUNCIL BILL NO. ORDINANCE NO. T"!' T Section 5. The following documents, attached hereto as Exhibit 4 and incorporated herein, are adopted as background documents to the Woodburn Comprehensive Plan: 4-A Economic Opportunities Analysis, ECONorthwest, May 2001 4-B Woodburn Population and Employment Projections memorandum, ECONorthwest, April 29, 2002 4-C Woodburn Occupation/Wage Forecast memorandum, ECONorthwest, March 20, 2003 4-D City of Woodburn Local Wetlands Inventory and Riparian Assessment, Shapiro 2000. 4-E Technical Report 1, Buildable Lands Inventory, including Housing/Lands Needs Model M, Winterbrook Planning, July 2005 (includes Buildable Lands Map) 4-F Technical Report 2, Woodburn Residential Land Needs Analysis, Winterbrook Planning, May 2005 4-G Technical Report 3, Potential UGB Expansion Area Analysis, Natural Resources Inventory, Winterbrook Planning, November 2003 (includes Soil Capability Classes Maps) 4-H Site Requirements For Woodburn Target Industries (ECONorthwest, 2003) 4-1 Citizen Involvement Report, City of Woodburn 2005 Comprehensive Plan Update, LCDC Periodic Review Work Order #0078, Work Task # 10, (Woodburn Community Development Department, October 2005 ) Section 6. This decision is consistent with the applicable Statewide Planning Goals based on evidence on the record as a whole and the following legislative findings, attached hereto as Exhibit 5 and incorporated herein, are made: 5-A Findinqs of Fact, demonstrating that Woodburn has completed its Periodic Review work program, and compliance with statewide Goals 1 through 8 and 11 through 13. 5-B Woodburn UGB Justification Report, Winterbrook Planning, October 2005, demonstrating compliance with statewide Goals 5, 7, 9, 10, 11, 12 and 14. 5-C Woodburn 2005 Comprehensive Plan Update, Explanation of Proposed Plan and Zoning Map Changes, Revised 2005, Woodburn Community Development Department. Page 3 - COUNCIL BILL NO. ORDINANCE NO. .,~ n T Section 7. This ordinance shall take effect on the date of an acknowledgement under the City's Periodic Review process. Approved as to form: /QJ.n-~ /0- 3'/- '201>S City Attorney Date Approved: Kathryn Figley, Mayor Passed by the Council Submitted to the Mayor Approved by the Mayor Filed in the Office of the Recorder ATTEST: Mary Tennant City Recorder City of Woodburn, Oregon ,-- .- Page 4 - COUNCIL BILL NO. ORDINANCE NO. n